402
Ariston High System Pressure / Expansion Fault

Furnace shows error 402, pressure rises rapidly during heating and may vent water from safety valve.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed expansion vessel, Overfilled system, Faulty pressure relief valve, Blocked expansion connection

How to Fix / Troubleshooting

Safety: Hot water under pressure can cause burns. Allow the system to cool before working on it.

  • Check cold pressure: When the system is cold, verify that the pressure is not above the recommended level. If over 2 bar, bleed water from a radiator to reduce pressure.
  • Observe pressure rise: During heating, if pressure climbs above 3 bar and the relief valve discharges, the expansion vessel may have lost its air charge.
  • Check expansion vessel: Locate the red expansion vessel inside or near the furnace. With the system depressurized, measure the air charge at the Schrader valve using a tire gauge. It should match the specification (often around 0.8–1.0 bar). If low or water comes out, the vessel is faulty.
  • Do not cap the relief valve: If the pressure relief valve is dripping constantly, it may need replacement. Never block or plug this valve.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Expansion Vessel