E12
Atlantic
Return Air Temperature Sensor Fault
Furnace displays E12, runs briefly, then shuts down with no heat reaching the home.
Advertisements
Possible Causes
Defective return air thermistor, Sensor wiring damaged or disconnected, Sensor installed in wrong location causing false readings
How to Fix / Troubleshooting
Safety: Turn off power before accessing the return air section.
Steps:
- Locate sensor: The return air temperature sensor is usually mounted near the return air inlet or inside the blower compartment.
- Inspect and reseat: Check the sensor body and wiring for damage. Reseat the connector on both the sensor and the Atlantic control board.
- Measure resistance: Compare the sensor resistance at room temperature to the Atlantic specification chart. Replace if readings are out of range.
- Check placement: Ensure the sensor is not touching hot components or located where it can be influenced by supply air leakage.
After repair: Restore power, clear the error by cycling power if needed, and verify stable operation.