C2
Bosch
Air Pressure Switch Opening During Run
Furnace shows C2; burner shuts down during operation
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Partial flue blockage, Condensate backing up into flue, Weak combustion fan, Intermittent air pressure switch
How to Fix / Troubleshooting
Safety: Shut off power and gas before inspection.
- Condensate system: Remove and clean the Bosch condensate trap. Flush with water and reassemble. Ensure the drain hose is not kinked or frozen.
- Flue inspection: Check for sagging horizontal runs where condensate can pool. Correct slope and support as needed.
- Switch and tubing: Replace any suspect tubing. If the switch shows signs of moisture inside, replace it.
If C2 recurs, a technician should measure fan pressure and verify correct flue sizing and installation.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Air Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements