Brötje No power to control board / control board failure

Boiler display is blank, no response to buttons, but mains power is present

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse, Faulty main switch, Loose power connector, Defective control board

How to Fix / Troubleshooting

Safety: Isolate the boiler from the mains before opening the electrical compartment.

  • 1. Check external power: Verify that the dedicated boiler circuit breaker is on and that there is mains voltage at the boiler terminals.
  • 2. Inspect main switch: Ensure the boiler’s on/off switch operates correctly and is not loose or burnt.
  • 3. Internal fuse: Locate and check the internal fuse(s) on the Brötje control board. Replace only with the same type and rating. If it blows again, a deeper fault exists.
  • 4. Control board: If power and fuse are OK but the display remains dead, the control board is likely defective and must be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements