Brötje
Short cycling
Boiler frequently cycles on and off with short run times, no error code
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Oversized boiler, Incorrect control settings, Low system water volume, Thermostat hysteresis too small
How to Fix / Troubleshooting
Safety: Adjust only user-accessible settings unless you are a trained technician.
- 1. Check room thermostat: Increase the differential/hysteresis if adjustable to reduce rapid cycling.
- 2. Adjust heating curve: Lower the heating curve slightly so the boiler runs longer at lower output.
- 3. Increase system volume: In some cases, adding a buffer tank or additional radiators can help; consult a heating engineer.
- 4. Pump setting: Ensure the pump is set appropriately to distribute heat quickly.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Room Thermostat / Controller
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements