A09
Brötje
Flow temperature sensor error
Boiler locks out with A09, display may indicate flow sensor fault
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC flow sensor, Loose sensor clip on flow pipe, Broken sensor cable, Faulty control board input
How to Fix / Troubleshooting
Safety: Isolate power and allow the flow pipe to cool before touching.
- 1. Locate flow sensor: On Brötje boilers, the flow NTC is usually clipped to the flow pipe leaving the heat exchanger.
- 2. Check mounting: Ensure the sensor is firmly attached and has good thermal contact with the pipe. Refit or replace the clip if loose.
- 3. Inspect cable: Follow the cable back to the PCB, checking for damage or disconnection.
- 4. Test sensor: Measure resistance at ambient temperature and compare with Brötje NTC tables. Replace the flow temperature sensor if readings are incorrect.
- 5. Control board: If a known-good sensor still gives A09, the control board analogue input may be defective and require replacement.