A10
Brötje
Return temperature sensor error
Display shows A10, return temperature sensor fault, boiler stops
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC return sensor, Poor contact to return pipe, Damaged wiring harness, Control board failure
How to Fix / Troubleshooting
Safety: Turn off power and let the return pipe cool.
- 1. Locate return sensor: The return NTC on Brötje units is typically clipped to the return pipe entering the heat exchanger.
- 2. Check attachment: Ensure the sensor is properly clipped and insulated from ambient air.
- 3. Inspect wiring: Look for mechanical damage, pulled cables, or loose plugs at the PCB.
- 4. Measure resistance: Compare measured resistance to the Brötje NTC curve. Replace the return temperature sensor if out of tolerance.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Return Temperature Sensor (NTC)
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements