A20
Brötje Gas pressure supervision fault

Display shows A20, gas pressure switch fault (if fitted)

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Insufficient gas supply pressure, Faulty gas pressure switch, Blocked pressure tubing, Incorrect switch setting

How to Fix / Troubleshooting

Safety: Work on gas components only if qualified. Shut off gas and power before opening gas train.

  • 1. Check gas supply: Ensure the main gas cock is open and that other gas appliances operate normally.
  • 2. Inspect pressure switch tubing: Check the small tubes from the gas valve to the pressure switch for blockage or damage.
  • 3. Test switch: A technician can measure continuity across the switch at known pressures. Replace the Brötje gas pressure switch if it does not operate correctly.
  • 4. Adjust or replace: Do not alter factory settings unless following Brötje commissioning instructions with proper instruments.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Pressure Switch
Check Price on Amazon