Possible Causes
Blocked circulation, Closed valves, Pump failure, Air in system, Faulty limit thermostat
How to Fix / Troubleshooting
Safety: Allow the boiler to cool fully before resetting any limit devices.
- 1. Check system valves: Ensure all main heating circuit valves are open.
- 2. Verify pump operation: Confirm the circulation pump runs when there is a heat demand.
- 3. Bleed air: Bleed radiators and automatic air vents.
- 4. Reset limit: Press the manual reset on the limit thermostat. If it trips again, find and correct the circulation issue.