Brötje
Air lock / circulation imbalance
Radiators on upper floors cold while lower floors heat normally
Advertisements
Possible Causes
Air trapped in upper circuits, Insufficient pump head, Partially closed balancing valves, Blocked dirt separator
How to Fix / Troubleshooting
Safety: System water may be hot; use a cloth when bleeding radiators.
- 1. Bleed upper radiators: Starting from the top floor, bleed each radiator until water flows without air.
- 2. Check system pressure: After bleeding, top up pressure to the recommended level.
- 3. Pump setting: Increase the pump speed or head setting on the Brötje pump if adjustable.
- 4. Clean dirt separator: If fitted, isolate and clean the dirt separator or filter on the return line.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Dirt Separator / System Filter
Check Price on Amazon