Bryant
Thermostat or Control Calibration Issue
Furnace cycles on and off rapidly (every few minutes) and the thermostat temperature overshoots or undershoots.
Advertisements
Possible Causes
Incorrect thermostat cycle rate setting, thermostat located in drafty area, incompatible thermostat with Bryant communicating furnace
How to Fix / Troubleshooting
Safety first: Turn off power to the furnace before changing thermostat wiring.
- Check thermostat settings: In the thermostat installer menu, set the system type to gas furnace and adjust cycles per hour to the manufacturer-recommended value (often 3–5 for gas).
- Relocate thermostat: Avoid mounting near exterior doors, windows, or supply registers.
- Compatibility: Communicating Bryant Evolution/Connex furnaces should use the matching Bryant communicating thermostat, not a generic model.
If cycling issues persist with correct thermostat and settings, the furnace control board may need evaluation.