Bryant
Insufficient Airflow
Furnace produces heat but airflow from registers is weak; some rooms are cold.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty blower wheel, undersized or restricted ductwork, failing blower motor capacitor, incorrect blower speed setting
How to Fix / Troubleshooting
Safety first: Turn off power before removing the blower assembly.
- Filter and registers: Replace the filter and open all supply and return registers fully.
- Inspect blower wheel: Remove the blower assembly and check for heavy dust buildup on the wheel blades. Clean thoroughly with a brush and vacuum.
- Check capacitor (PSC motors): Locate the blower motor run capacitor. If it is bulging or leaking, replace it with the same microfarad (µF) rating and voltage.
- Verify blower speed tap: On multi-speed Bryant furnaces, confirm the correct speed tap is connected for heating per the wiring diagram.
If airflow remains poor, a ductwork evaluation may be needed to correct design or installation issues.
Advertisements
Repair Difficulty
Medium
3/5