O5 code, furnace does not start, safety chain open
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Turn off power. Never bypass safety switches to keep the furnace running.
Steps:
- Check access panels: Ensure all Buderus burner and control doors are properly closed and latched. Some models have door interlock switches.
- Inspect high-limit and flue switches: Locate the manual reset high-limit and flue safety switches. If a red or black reset button is present, press it after the unit has cooled.
- Wiring check: Follow the low-voltage safety loop wiring and look for loose spade connectors or broken wires.
If O5 returns after resets and wiring checks, a safety device may be tripping due to a real fault (overheat, blocked flue) and should be diagnosed by a professional.