P2
Buderus Condensate Drain Fault

P2 code, condensate present, furnace may shut down or leak water internally

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked condensate trap, Kinked condensate hose, Frozen or clogged external drain, Faulty condensate level sensor

How to Fix / Troubleshooting

Safety: Turn off power. Condensate is mildly acidic; wear gloves and eye protection.

Steps:

  • Locate condensate trap: On Buderus condensing furnaces, the trap is usually a plastic assembly at the bottom of the heat exchanger or flue collector.
  • Clean trap: Remove the trap per the manual. Flush it with clean water to remove sludge and debris. Reassemble carefully, ensuring all seals are tight.
  • Check hoses: Inspect condensate hoses for kinks, sags, or blockages. Clear any obstructions and ensure proper slope to the drain.
  • Verify drain outlet: Make sure the drain line is not frozen or blocked where it discharges.

If P2 persists, the condensate level sensor or float switch may be faulty and should be tested and replaced by a technician.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Buderus Condensate Trap Assembly
Check Price on Amazon