P3
Buderus Outdoor Temperature Sensor Fault (Weather Compensation)

P3 error, furnace output limited, may not reach set temperature

Advertisements

Possible Causes

Failed Buderus outdoor sensor, Broken sensor cable, Incorrect sensor location, Shorted sensor wiring

How to Fix / Troubleshooting

Safety: Turn off power before working on low-voltage outdoor wiring.

Steps:

  • Locate sensor: The Buderus outdoor sensor is usually mounted on a north or northwest exterior wall, away from direct sun and heat sources.
  • Inspect cable: Check for damage from weather, animals, or fasteners. Repair or replace damaged sections.
  • Check connections: Ensure the sensor wires are firmly connected to the designated terminals on the Buderus control.
  • Resistance test: With power off, measure sensor resistance and compare to Buderus outdoor sensor charts.

If the sensor is defective, replace it with the correct Buderus outdoor sensor model.