Buderus
Short Cycling Due to Control or Sizing Issues
Furnace is short cycling, turning on and off frequently without reaching set temperature
Advertisements
Possible Causes
Oversized furnace, Thermostat located in poor position, Incorrect heating curve on Buderus control, Flow restriction causing rapid temperature rise
How to Fix / Troubleshooting
Safety: Normal short cycling is not immediately dangerous but reduces efficiency and wear.
Steps:
- Thermostat location: Ensure the thermostat is not near heat sources, drafts, or direct sunlight. Relocate if necessary.
- Adjust control settings: On Buderus Logamatic controls, adjust the heating curve and differential to reduce rapid cycling.
- Check flow: Verify all zones are open and radiators are not shut off, which can cause quick temperature rise at the furnace.
If cycling remains excessive, a technician should evaluate system design and control programming.
Advertisements
Repair Difficulty
Easy
2/5