Insufficient Heat Output
Furnace runs but house is not heating adequately, radiators or ducts are lukewarm
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect boiler temperature setting on Buderus control, Air in heating system, Undersized circulation pump, Mixing valve stuck partially closed
How to Fix / Troubleshooting
Safety: Turn off power before opening panels; be cautious of hot water and surfaces.
Steps:
- Check setpoints: On the Buderus control (e.g., Logamatic), verify that the heating curve and maximum flow temperature are set appropriately for your climate and emitters.
- Bleed radiators: Use radiator bleed valves to remove trapped air until water flows steadily. Refill system to proper pressure afterward.
- Inspect circulation pump: Confirm the Buderus pump is running and not set to an excessively low speed. Many pumps have adjustable speed settings.
- Check mixing valve: If a 3-way or 4-way mixing valve is installed, ensure it is not stuck in a low-temperature position. Manually exercise the valve if possible.
If performance remains poor, a technician should perform a full hydraulic and combustion check.