Buderus
Short Cycling on Flame Loss
Furnace starts then shuts off after a few seconds, no error code displayed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty flame sensor, Poor grounding of burner, Unstable gas pressure, Partially blocked burner
How to Fix / Troubleshooting
Safety: Turn off power and gas before opening the burner compartment.
Steps:
- Clean flame sensor: Remove and gently clean the Buderus flame rod with fine steel wool. Reinstall securely.
- Check burner ground: Ensure the burner assembly has a solid metal-to-metal connection to the furnace chassis. Tighten mounting screws and clean rust.
- Inspect burner: Look for rust flakes or debris on the burner head. Clean with a soft brush and vacuum.
- Monitor gas supply: If other gas appliances flicker or drop out, contact your gas supplier.
If short cycling continues, a technician should check combustion and gas valve operation.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Flame Sensor Rod
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements