Possible Causes

Dirty flame sensor, Poor grounding of burner, Unstable gas pressure, Partially blocked burner

How to Fix / Troubleshooting

Safety: Turn off power and gas before opening the burner compartment.

Steps:

  • Clean flame sensor: Remove and gently clean the Buderus flame rod with fine steel wool. Reinstall securely.
  • Check burner ground: Ensure the burner assembly has a solid metal-to-metal connection to the furnace chassis. Tighten mounting screws and clean rust.
  • Inspect burner: Look for rust flakes or debris on the burner head. Clean with a soft brush and vacuum.
  • Monitor gas supply: If other gas appliances flicker or drop out, contact your gas supplier.

If short cycling continues, a technician should check combustion and gas valve operation.