Buderus
Air in Hydronic System
Gurgling or rushing water sounds in pipes and radiators when furnace runs
Advertisements
Possible Causes
Insufficient bleeding after filling, Automatic air vent failure, Low system pressure drawing in air, Micro-leaks on suction side of pump
How to Fix / Troubleshooting
Safety: Be cautious of hot water when bleeding radiators.
Steps:
- Bleed radiators: Starting with upper floors, open bleed valves until water flows without air. Close valves and top up system pressure as needed.
- Check automatic air vents: Ensure caps on auto vents near the Buderus furnace are slightly open to allow air release.
- Maintain pressure: Keep system pressure at the recommended level to prevent air ingress.
Persistent air problems may indicate a leak or failing air separator that should be addressed by a technician.