42
Carrier Inducer Motor Fault

Furnace LED shows code 42 (inducer motor fault). Furnace will not ignite; inducer may not start or may start then stop.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed inducer motor, seized inducer wheel, blocked inducer housing, faulty inducer relay on control board

How to Fix / Troubleshooting

Safety first: Turn off power and gas. The inducer is part of the combustion system.

  • Listen for inducer: With a call for heat, listen for the inducer fan starting. If you hear only a hum or nothing at all, the motor may be failed.
  • Inspect inducer housing: Remove the burner door and visually inspect the inducer assembly for cracks, water leaks, or debris.
  • Check condensate lines: On condensing models, ensure the condensate drain from the inducer/collector box is clear. A backed-up drain can flood the inducer.
  • Verify power to inducer (advanced): A technician can check for 120V at the inducer motor leads when there is a call for heat. If voltage is present but the motor does not run, the inducer needs replacement.

Inducer replacement involves sealing the combustion chamber and vent connections; have this done by a qualified HVAC technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inducer Motor Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements