43
Carrier Pressure Switch Calibration / Limit Fault

Furnace LED shows code 43 (pressure switch calibration fault or limit circuit fault depending on model).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect pressure switch for furnace model, miswired pressure switch leads, defective pressure switch, control board sensing error

How to Fix / Troubleshooting

Safety first: Turn off power before working on pressure switches or wiring.

  • Verify model and switch rating: Check the Carrier model number and compare the installed pressure switch part number to the furnace parts list or label. Using a non-OEM or incorrect rating switch can cause this code.
  • Inspect wiring: Ensure the pressure switch wires are on the correct terminals as shown on the Carrier wiring diagram inside the blower door.
  • Check tubing and ports: Confirm that the tubing is connected to the correct port on the inducer or collector box and that ports are not plugged.
  • Reset power: After corrections, turn power off for 30 seconds, then back on and call for heat to see if the code clears.

If the correct switch is installed and the code persists, the pressure switch or control board may require replacement by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements