E06
Cointra
Return / Room Temperature Sensor Fault
Furnace shows E06, heating stops, fan may continue to run for a short time.
Advertisements
Possible Causes
Open or shorted room NTC sensor, Broken sensor cable, Incorrect sensor placement, Faulty control board
How to Fix / Troubleshooting
Safety: Turn off power before removing any covers or wall sensors.
Steps:
- Identify the sensor: The room NTC may be built into the furnace or installed as a remote wall sensor. Locate the small sensor housing and its cable.
- Check wiring: Inspect the cable from the sensor to the Cointra control board for cuts, staples through the wire, or loose terminals. Reseat the connector.
- Check sensor location: Ensure the room sensor is not installed near heat sources, direct sunlight, or behind curtains, which can cause incorrect readings and faults.
- Test or replace sensor: If you have a multimeter, measure resistance and compare to the Cointra NTC chart. Replace the sensor if readings are abnormal.
Professional help: If wiring and sensor are good, the control board may have a defective sensor input and should be diagnosed by a technician.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room NTC Temperature Sensor