E15
Cointra Outdoor Temperature Sensor Fault (if equipped)

Furnace displays E15, unit may continue to run at reduced performance.

Advertisements

Possible Causes

Open or shorted outdoor NTC sensor, Damaged sensor cable, Incorrect sensor placement, Faulty control board input

How to Fix / Troubleshooting

Safety: Turn off power before accessing sensor wiring.

Steps:

  • Locate outdoor sensor: Find the small sensor mounted on an exterior wall, away from direct sunlight and heat sources.
  • Inspect cable and connections: Check for weather damage, loose terminals, or corrosion at junction boxes.
  • Replace sensor if needed: If the sensor body is cracked or readings are clearly wrong (e.g., showing extreme temperatures), replace it with a Cointra-compatible outdoor NTC.

Professional service: If a new sensor does not resolve E15, the control board may have a defective sensor input.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Outdoor NTC Temperature Sensor
Check Price on Amazon