32
Comfortmaker Low Heat or High Heat Pressure Switch Fault / Partial Restriction

LED flashes code 32; furnace may run blower unexpectedly or fail to start a heat cycle.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Partially blocked vent or intake, Incorrect pressure switch for Comfortmaker model, Loose pressure switch wiring, Condensate partially blocking pressure port

How to Fix / Troubleshooting

Safety: Turn off power and gas before servicing. Do not bypass pressure switches.

Steps:

  • Check intake and exhaust (2-pipe systems): Ensure both intake and exhaust PVC pipes are clear and properly terminated. Remove any screens clogged with debris.
  • Inspect pressure switch rating: Verify the part number on the pressure switch matches the Comfortmaker model's specifications. An incorrect switch can cause nuisance faults.
  • Clean pressure ports: Remove tubing and gently clean the ports on the inducer or collector box with a small drill bit or wire.
  • Check condensate routing: Confirm that condensate hoses are not sagging or partially filled with water near the pressure switch port.

When to call a technician: If the code persists after cleaning and inspection, a technician should measure actual draft pressures and replace the pressure switch or correct venting issues.

Advertisements

Repair Difficulty