11 FLASHES
Concord
Limit Switch Circuit Lockout
Furnace does not respond to thermostat; status LED shows 11 flashes repeating.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open high limit or rollout switch, Loose wiring in limit circuit, Faulty integrated furnace control board, Overheating due to airflow issues
How to Fix / Troubleshooting
Safety: Turn off power before accessing the control board or limit switches.
Steps:
- Locate all limit devices: Identify the main high limit on the heat exchanger panel and any rollout switches near the burners. Check for manual reset buttons on rollout switches.
- Check continuity: With power off, use a multimeter to check continuity across each limit. Any open device (no continuity) must be investigated. Manual-reset rollout switches that are tripped should only be reset after determining the cause.
- Inspect wiring: Follow the limit circuit wiring from the control board through each limit device. Tighten loose spade connectors and repair damaged wires.
- Address overheating causes: Replace dirty filters, open closed registers, and verify blower operation.
Note: If all limits are closed and wiring is intact but the board still shows a limit lockout, the control board may be defective.