Door Switch or Airflow Restriction Issue
Furnace starts but shuts down immediately when the blower door is installed; runs with door removed (defeating switch).
Advertisements
Possible Causes
Faulty blower door safety switch, Cabinet air leakage affecting pressure switch, Misaligned door causing switch to open intermittently
How to Fix / Troubleshooting
Safety: Never operate the furnace with the blower door removed or the door switch bypassed except briefly for testing by a qualified person.
Steps:
- Inspect door switch: Check that the door switch actuator is properly aligned with the door. Replace the switch if it is loose, broken, or intermittent.
- Check cabinet fit: Ensure the blower door is fully seated and latched. Bent panels may need adjustment.
- Airflow: If the furnace only runs with the door off, there may be severe return air restriction causing negative pressure in the cabinet. Check filter, returns, and duct sizing.