CTC Uneven Heating / Airflow Imbalance

Furnace runs but some rooms are too hot while others are too cold.

Advertisements

Possible Causes

Improper duct balancing, Closed or undersized registers, Dirty filter, Blower speed not optimized

How to Fix / Troubleshooting

Safety first: Turn off power before adjusting blower speed on the control board.

Steps:

  • Ensure all supply registers and returns are open; avoid closing too many registers, which can affect furnace operation.
  • Replace the air filter.
  • Partially close registers in overheated rooms to push more air to colder rooms, but do not close more than 20–30% of total registers.
  • A technician can adjust blower speed taps or ECM profiles on the CTC control board and evaluate duct design for better balance.