Daikin Control Signal / Thermostat Circuit Failure

Daikin furnace will not respond to thermostat; thermostat appears normal but no heating occurs.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken thermostat wire between R and W, Tripped float switch in condensate line interrupting R circuit, Blown 24V fuse on Daikin control board, Faulty thermostat relay contacts

How to Fix / Troubleshooting

Safety: Turn off power before working on low-voltage wiring to avoid shorting the transformer.

Steps to check:

  • Check 24V fuse: Inspect and replace the low-voltage fuse on the Daikin board if blown, using the same rating.
  • Float switch: If a condensate float switch is wired in series with R, ensure the condensate pan is not full and the switch is not tripped.
  • Thermostat test: At the furnace board, temporarily jumper R to W to simulate a heat call. If the furnace starts, the thermostat or thermostat wiring is likely faulty.

Replace the thermostat or repair wiring as needed. If jumping R to W does not start the furnace, the issue is within the Daikin furnace controls and requires professional diagnosis.