E3
Daikin
High Discharge Air Temperature / Overheat
Daikin furnace shows E3; unit may shut down on high temperature or fail to complete a heating cycle.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Restricted airflow due to dirty filter or blocked ducts, Oversized furnace with low airflow settings, Failed indoor fan not delivering required CFM, Faulty discharge air thermistor giving false high reading
How to Fix / Troubleshooting
Safety: Components may be hot. Turn off power and allow the furnace to cool before working on it.
Steps to check:
- Airflow checks: Replace the furnace filter, open all registers, and ensure return grilles are not blocked.
- Blower speed settings: On variable-speed Daikin furnaces, verify that the blower speed tap or DIP switch settings are appropriate for the duct system (technician task).
- Inspect discharge sensor: Confirm the discharge air thermistor is properly located in the supply plenum and not touching the heat exchanger or metal surfaces that could cause localized overheating.
- Temperature rise: A technician should measure the temperature rise across the furnace and compare it to the rating plate. Excessive rise indicates airflow problems.
Persistent E3 faults require professional evaluation of duct design, blower performance, and sensor operation.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Daikin Discharge Air Thermistor / ECM Blower Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements