Daikin gas furnace will not start; control board shows U0, inducer may start briefly then stop, no ignition.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off electrical power to the furnace and close the gas shutoff valve before touching any gas components. If you smell gas, evacuate and contact your gas supplier or a licensed technician immediately.
Steps to check:
- Verify gas shutoff: Locate the manual gas shutoff valve near the furnace. Ensure the handle is parallel to the gas pipe (open). If perpendicular, turn it slowly to the open position.
- Check other gas appliances: Confirm that other gas appliances (stove, water heater) in the home are working. If they are not, the issue may be with the building gas supply and not the furnace.
- Inspect gas line to furnace: Look for obvious kinks, crushing, or damage to the flexible gas connector feeding the Daikin furnace gas valve.
- Reset power: Restore power to the furnace, then turn the thermostat to HEAT and raise the setpoint. Observe if the U0 code clears after a power cycle.
- Check inlet gas pressure (pro only): A licensed technician should connect a manometer to the inlet test port on the Daikin gas valve and verify pressure matches the rating plate. Incorrect pressure indicates a supply or regulator problem.
Do not attempt to disassemble or replace the gas valve yourself unless you are qualified. Gas valve replacement and pressure adjustment must be done by a licensed HVAC technician.