E11
Danfoss Return Air NTC Sensor Error

Furnace intermittently shuts down with E11, indicating a return air temperature sensor fault

Advertisements

Possible Causes

Failed Danfoss return air sensor, sensor lead shorted to chassis, connector partially unplugged from control board, sensor exposed to radiant heat

How to Fix / Troubleshooting

Safety first: Turn off power before accessing the control or sensor wiring.

Steps:

  • Locate return air sensor: Find the Danfoss NTC sensor mounted in the return air duct or blower compartment.
  • Inspect mounting: Ensure the sensor is properly inserted into the airstream and not touching hot metal surfaces that could distort readings.
  • Check wiring: Follow the sensor cable to the control board. Look for insulation damage or points where the cable may be pinched. Reseat the connector.
  • Replace if defective: If the sensor shows open or short circuit when measured with a meter, replace it with the specified Danfoss return air sensor.
  • Reset and monitor: Clear the E11 code and observe operation over several cycles to confirm stability.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Danfoss Return Air Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements