E12
Danfoss
Outdoor Sensor Failure / Open or Short
Furnace displays E12 and will not fire, indicating an outdoor temperature sensor fault (for weather-compensated Danfoss systems)
Advertisements
Possible Causes
Damaged outdoor NTC sensor, cable cut or chewed, incorrect sensor type installed, water ingress into sensor housing
How to Fix / Troubleshooting
Safety first: Turn off power before working on outdoor wiring.
Steps:
- Inspect outdoor sensor: Locate the Danfoss outdoor sensor on the north-facing exterior wall. Check that the housing is intact and not filled with water or insects.
- Check cable: Follow the cable back toward the furnace, looking for mechanical damage. Repair or replace damaged sections.
- Verify connections: At the control board, ensure the outdoor sensor wires are on the correct terminals and firmly tightened.
- Replace sensor if needed: If the sensor is physically damaged or tests open/short with a meter, install a new Danfoss outdoor sensor of the correct resistance curve.
- Reset controller: Restore power, clear E12, and verify that the displayed outdoor temperature is reasonable.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Danfoss Outdoor Temperature Sensor
Check Price on Amazon