E14
Danfoss
Flue Gas NTC Sensor Error
Furnace shows E14, indicating a flue gas temperature sensor fault
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed Danfoss flue gas sensor, sensor lead damaged by heat, poor contact with flue pipe, wiring shorted to metal
How to Fix / Troubleshooting
Safety first: Turn off power and allow the flue to cool before touching any components.
Steps:
- Locate flue sensor: Find the Danfoss flue gas temperature sensor inserted into the flue pipe near the furnace.
- Inspect mounting and wiring: Ensure the sensor is fully inserted and clamped. Check the cable for heat damage or melted insulation. Reroute away from hot surfaces if necessary.
- Check connector: At the control board, reseat the flue sensor connector and inspect for corrosion.
- Replace if faulty: If the sensor is physically damaged or tests open/short, replace it with the correct Danfoss flue gas sensor model.
- Reset and verify: Clear E14 and monitor flue temperature readings during operation to ensure they are within normal range.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Danfoss Flue Gas Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.