E17
Danfoss Safety Loop Open / External Interlock Fault

Furnace shows E17 and stops, indicating a safety chain or external interlock open

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open door switch, tripped auxiliary limit switch, external emergency stop activated, broken wire in safety loop

How to Fix / Troubleshooting

Safety first: Do not bypass safety devices. Identify and correct the cause of the open safety circuit.

Steps:

  • Check access panels: Ensure all furnace doors and panels are properly closed so that door interlock switches are engaged.
  • Inspect auxiliary limits: Look for manual-reset limit switches on the blower housing or near the burner. If a red reset button is present and popped, press it once to reset. Investigate why it tripped (overheating, blocked airflow).
  • Verify external emergency stop: Confirm that any external emergency stop buttons or boiler room safety switches are in the RUN position.
  • Trace safety wiring: Using the wiring diagram, follow the safety loop wiring from the Danfoss controller through all devices. Look for loose connections or broken wires.
  • Reset and test: After restoring the safety loop, reset the controller and observe operation. If E17 recurs, a safety device may be intermittently opening and should be tested by a technician.