E19
Danfoss Gas Valve Modulation Error

Furnace shows E19, indicating a modulation or gas valve positioning fault on a modulating Danfoss burner

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty modulating gas valve actuator, feedback potentiometer failure, broken linkage between actuator and valve, incorrect calibration

How to Fix / Troubleshooting

Safety first: Turn off power and gas. Modulating gas valve adjustments must be performed by qualified personnel.

Steps:

  • Visual inspection: Locate the modulating gas valve and actuator. Check for obvious mechanical damage or disconnected linkages.
  • Check actuator wiring: Inspect the control cable from the Danfoss controller to the actuator for damage or loose connectors.
  • Listen for movement: During a call for heat (with panels in place), you may hear the actuator move. No movement or erratic noise suggests actuator failure.
  • Do not adjust settings: Do not attempt to recalibrate or mechanically adjust the gas valve without combustion test equipment and the Danfoss service manual.

If E19 persists, the modulating gas valve assembly or actuator should be replaced and commissioned by a licensed technician.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Modulating Gas Valve Actuator
Check Price on Amazon

We may earn a commission from links on this page.