Danfoss No Power to Furnace

Furnace will not start at all, no lights on the Danfoss controller, blower and burner inactive

Advertisements

Possible Causes

Tripped breaker, blown internal fuse, faulty service switch, loose line voltage connection, failed transformer

How to Fix / Troubleshooting

Safety first: Turn off the breaker before opening electrical compartments. Use a non-contact voltage tester if available.

Steps:

  • Check breaker and switch: Verify the furnace breaker is ON and the furnace service switch is in the ON position.
  • Inspect internal fuse: Many Danfoss controls have an internal low-voltage fuse. With power off, remove and visually inspect the fuse. Replace only with the same type and rating.
  • Check door interlock: Ensure the blower door is properly installed to engage any door switch.
  • Verify transformer output: A technician can measure the low-voltage transformer output to confirm it is supplying the control.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Low-Voltage Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements