Danfoss Condensate Leak / Drain Misrouting

Water leaking from the base of the furnace or around the condensate drain

Advertisements

Possible Causes

Cracked condensate trap, loose drain tubing, blocked drain line, missing trap on condensate outlet

How to Fix / Troubleshooting

Safety first: Turn off power. Avoid standing water near electrical components.

Steps:

  • Locate leak source: Remove the lower panel and observe where water is originating—trap, tubing, or heat exchanger drain port.
  • Clean and clear drain: Remove the condensate trap and flush it. Use a wet/dry vacuum on the drain line to clear blockages.
  • Check tubing connections: Ensure all hoses are fully seated on their barbs and secured with clamps if necessary.
  • Replace damaged parts: If the trap or tubing is cracked, replace with compatible condensate components rated for condensing furnaces.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Condensate Drain Tubing
Check Price on Amazon