43
Day & Night
Two-Stage Pressure Switch / Venting Fault
Furnace LED flashes code 43; indicates pressure switch or venting problem during high-fire or low-fire operation on two-stage models.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrectly wired two-stage pressure switches, partially blocked vent, undersized intake/exhaust, weak inducer on high stage
How to Fix / Troubleshooting
Safety first: Turn off power before accessing internal components.
- Verify vent sizing: Compare vent pipe size and length to the installation label on the furnace. Excessive length or too many elbows can cause draft issues.
- Inspect both pressure switches: On two-stage Day & Night furnaces, there may be separate switches for low and high fire. Ensure all tubing and wires are correctly connected per the wiring diagram.
- Check outdoor terminations: Confirm both intake and exhaust are clear and properly spaced.
- Reset and test: After inspection, reset power and call for heat, observing whether the furnace can transition between stages without fault.
Stage-specific pressure problems require measurement with a manometer. A technician should verify switch setpoints and inducer performance.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
High-Stage Pressure Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements