A14
De Dietrich Insufficient Circulation / Delta T Fault

Boiler shows A14, heating limited or stopped, often with high return temperature

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Closed radiator valves in De Dietrich heating circuit, Blocked dirt separator or filter, Undersized or stuck pump speed, Sludge in system restricting flow

How to Fix / Troubleshooting

Safety: Allow the system to cool before opening any filters or valves.

Steps:

  • Open valves: Ensure all radiator and underfloor heating valves are open, especially near the boiler.
  • Clean system filter: If a magnetic filter or dirt separator is installed, isolate it, depressurise if needed, and clean out sludge and debris.
  • Check pump setting: On variable‑speed pumps, ensure the speed is not set too low. Adjust according to the installation manual.
  • Bleed system: Remove air from high points and radiators.

Professional help: Persistent flow issues may require a power flush and pump or pipework modifications.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Circulation Pump
Check Price on Amazon