A15
De Dietrich External Control / Thermostat Communication Fault

Boiler displays A15, no response to thermostat, heating demand not recognised

Advertisements

Possible Causes

Open circuit in room thermostat wiring, Faulty De Dietrich room controller, Incorrect parameter setting for control type, Short circuit on control terminals

How to Fix / Troubleshooting

Safety: Isolate power before working on control wiring.

Steps:

  • Check controller display: Ensure the De Dietrich room thermostat or controller is powered and not showing its own error.
  • Inspect wiring: At the boiler control terminals, verify that the thermostat wires are securely connected and not damaged.
  • Bypass test (qualified persons only): Briefly bridge the room thermostat terminals at the boiler to simulate a heat demand. If the boiler starts, the external control or wiring is faulty.
  • Check settings: In the boiler menu, confirm that the correct control mode (on/off, OpenTherm, BUS) is selected for your controller.

Professional help: For BUS or modulating controls, a technician may need to diagnose communication issues and replace the controller or PCB.