E04
De Dietrich
Condensate Drain Fault
Boiler displays E04, condensate alarm, boiler stops
Advertisements
Possible Causes
Blocked condensate trap on De Dietrich condensing boiler, Frozen condensate pipe, Incorrectly installed condensate line (no fall), Faulty condensate level sensor (if fitted)
How to Fix / Troubleshooting
Safety: Condensate is mildly acidic. Wear gloves and eye protection when handling.
Steps:
- Inspect condensate pipe: Check the plastic pipe from the boiler to the drain for kinks, blockages, or freezing (common in cold weather). Thaw gently with warm towels if frozen; do not use open flame.
- Clean condensate trap: Remove the trap under the boiler, empty it, and rinse out sludge. Refill with clean water before refitting to maintain the water seal.
- Check pipe slope: Ensure the condensate pipe runs downhill continuously to the drain with adequate fall.
- Reset boiler: Restore power and reset. Confirm that condensate flows freely when the boiler runs.
Professional help: If E04 persists, a technician should check any condensate level sensors and the internal routing.