E06
De Dietrich
BUS Communication Fault
Boiler displays E06, communication error with remote controller or cascade manager
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken BUS cable between De Dietrich boiler and controller, Incorrect BUS polarity, Too many devices on BUS without proper addressing, Faulty controller
How to Fix / Troubleshooting
Safety: Isolate power before working on low‑voltage BUS wiring.
Steps:
- Check cable: Inspect the BUS cable for damage, loose terminals, or reversed polarity (A/B swapped).
- Reduce devices: If multiple devices are connected, temporarily disconnect all but one to see if communication is restored.
- Restart system: Power down both boiler and controller, then power up the boiler first, followed by the controller.
Professional help: BUS diagnostics and addressing should be done by a technician familiar with De Dietrich control systems.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Room Controller BUS Module