E10
De Dietrich
Internal Boiler Temperature Monitoring Fault
Boiler displays E10, internal temperature sensor or limit fault
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective internal NTC on De Dietrich heat exchanger, Wiring fault to sensor, PCB analogue input failure, Sensor not correctly mounted
How to Fix / Troubleshooting
Safety: Isolate power and allow boiler to cool before accessing sensors.
Steps:
- Locate internal sensor: Identify the NTC sensor on the heat exchanger or flow pipe.
- Check mounting and wiring: Ensure good contact with the metal surface and secure wiring.
- Reset boiler: After reseating, restore power and reset.
Professional help: If E10 persists, a technician should test the sensor resistance and replace the sensor or PCB as needed.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Primary NTC Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements