De Dietrich
Control Signal Not Reaching Boiler
Furnace does not respond to room thermostat, stays off even when there is demand
Advertisements
Possible Causes
Flat batteries in wireless De Dietrich thermostat, Lost pairing between thermostat and receiver, Broken thermostat cable, Incorrect control mode setting
How to Fix / Troubleshooting
Safety: Isolate power before working on wiring; wireless checks can be done with power on.
Steps:
- Check thermostat: Replace batteries, ensure it is set to heating mode and above room temperature.
- Check receiver: Verify that the receiver near the boiler shows a demand signal (LED or icon) when the thermostat calls for heat.
- Re-pair devices: Follow the De Dietrich manual to re‑pair the wireless thermostat and receiver.
- Wired systems: For wired thermostats, check that the cable is intact and firmly connected at both ends.
Professional help: If the boiler still does not respond, the control PCB or thermostat may need replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Room Thermostat / Receiver
Check Price on Amazon
We may earn a commission from links on this page.