Dettson
No Power to Furnace
Dettson furnace will not start at all; no lights, no fan, completely dead.
Advertisements
Possible Causes
Tripped breaker or blown fuse, Furnace service switch off, Open internal fuse on control board, Loose power wiring in junction box
How to Fix / Troubleshooting
Safety first: Turn off the breaker before opening any electrical compartments.
- 1. Check breaker and service switch: Reset the furnace breaker and ensure the furnace disconnect or service switch is ON.
- 2. Inspect control board fuse: Remove the blower door and locate the low-voltage fuse (often 3–5A automotive style) on the control board. Replace if blown, but investigate the cause (shorted thermostat wire, etc.).
- 3. Verify line voltage: With a multimeter (if qualified), check for 120 VAC at the furnace junction box. If absent, contact an electrician.
- 4. Check door switch: Ensure the blower door is properly installed and engaging the door switch.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Control Board Fuse
Check Price on Amazon