E11
Dettson Supply Air Temperature Sensor Fault

Dettson furnace displays E11; blower may run at low speed continuously without heating.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted supply air temperature sensor, Disconnected sensor harness, Sensor mounted incorrectly in supply plenum, Faulty control board sensor input

How to Fix / Troubleshooting

Safety first: Turn off power before accessing the supply plenum or control board.

  • 1. Locate the supply air sensor: On some Dettson models, a thermistor or temperature probe is installed in the supply air plenum or on the discharge side of the furnace.
  • 2. Inspect wiring and connector: Ensure the sensor harness is plugged firmly into the control board and that the wires are not damaged.
  • 3. Check sensor placement: The sensor should be fully inserted into the airstream, not hanging loose or touching metal surfaces that could skew readings.
  • 4. Test sensor resistance: With power off, disconnect the sensor and measure resistance with a multimeter. Compare to Dettson specifications for room temperature. An open or shorted reading indicates a bad sensor.
  • 5. Replace sensor if defective: Install the correct Dettson replacement sensor, route wiring away from hot surfaces, and secure it properly.
  • 6. Reset and test: Restore power and run a heating cycle to confirm E11 is cleared.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Supply Air Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements