E13
Dettson Outdoor Temperature Sensor Fault (if equipped)

Dettson furnace displays E13; unit may short-cycle or not reach set temperature.

Advertisements

Possible Causes

Open or shorted outdoor sensor, Sensor cable damaged outdoors, Incorrect sensor type installed, Miswired sensor to control board

How to Fix / Troubleshooting

Safety first: Turn off furnace power before checking outdoor wiring.

  • 1. Locate outdoor sensor: Typically mounted on an exterior wall away from direct sunlight and exhaust vents.
  • 2. Inspect cable: Follow the sensor cable back toward the furnace. Look for damage from weather, UV, or animals. Repair or replace as needed.
  • 3. Check connections at control board: Ensure the sensor wires are landed on the correct terminals and are tight.
  • 4. Test sensor: Disconnect and measure resistance; compare to Dettson's temperature/resistance chart. Replace if out of range.
  • 5. Clear error: Restore power and verify that E13 clears and the furnace modulates or stages correctly.