E13
Dettson
Outdoor Temperature Sensor Fault (if equipped)
Dettson furnace displays E13; unit may short-cycle or not reach set temperature.
Advertisements
Possible Causes
Open or shorted outdoor sensor, Sensor cable damaged outdoors, Incorrect sensor type installed, Miswired sensor to control board
How to Fix / Troubleshooting
Safety first: Turn off furnace power before checking outdoor wiring.
- 1. Locate outdoor sensor: Typically mounted on an exterior wall away from direct sunlight and exhaust vents.
- 2. Inspect cable: Follow the sensor cable back toward the furnace. Look for damage from weather, UV, or animals. Repair or replace as needed.
- 3. Check connections at control board: Ensure the sensor wires are landed on the correct terminals and are tight.
- 4. Test sensor: Disconnect and measure resistance; compare to Dettson's temperature/resistance chart. Replace if out of range.
- 5. Clear error: Restore power and verify that E13 clears and the furnace modulates or stages correctly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outdoor Temperature Sensor
Check Price on Amazon