E18
Dettson Thermostat Type / Configuration Error

Dettson furnace shows E18; unit may not respond to thermostat changes.

Advertisements

Possible Causes

Incorrect thermostat type (heat pump vs. furnace), Misconfigured staging or fan control, Incompatible communicating thermostat, Incorrect dip switch settings on control board

How to Fix / Troubleshooting

Safety first: Turn off power to the furnace before changing control board settings.

  • 1. Verify thermostat compatibility: Confirm that the thermostat is rated for gas furnaces and matches the staging (single-stage, two-stage, modulating) of your Dettson unit.
  • 2. Check thermostat setup menu: Enter the installer setup on the thermostat and ensure system type, fan control, and number of stages are correctly configured.
  • 3. Inspect control board switches/jumpers: Compare dip switch or jumper positions on the Dettson control board to the installation manual for your model and thermostat type.
  • 4. Correct any mismatches: Adjust thermostat settings and control board configuration so they agree. Power cycle the furnace afterward.
  • 5. Replace incompatible thermostat: If the thermostat cannot be configured correctly, replace it with a Dettson-approved or standard furnace thermostat.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Thermostat
Check Price on Amazon

We may earn a commission from links on this page.