E20
Dettson Door Switch / Safety Interlock Open

Dettson furnace shows E20; unit may not start or may shut down unexpectedly.

Advertisements

Possible Causes

Loose or misaligned blower door, Faulty door safety switch, Broken switch actuator tab on door, Disconnected door switch wiring

How to Fix / Troubleshooting

Safety first: Always ensure the blower door is properly installed before operating the furnace.

  • 1. Reseat blower door: Remove and reinstall the blower compartment door, making sure it engages the door switch fully. Some doors must be slid into place then pushed firmly.
  • 2. Inspect door switch: Locate the door switch near the blower door edge. Check that the plunger moves freely and is not broken.
  • 3. Check wiring: Ensure the wires to the door switch are firmly connected and not damaged.
  • 4. Replace faulty switch: If the switch does not click or fails continuity testing when pressed, replace it with the correct Dettson-compatible door switch.
  • 5. Test operation: With the door properly installed, restore power and confirm E20 is cleared.