11
Ducane
No Call for Heat / Idle State
Code 11, no response from furnace when thermostat calls for heat, LED indicates no previous faults
Advertisements
Possible Causes
Thermostat not sending W call, Broken W wire between thermostat and Ducane control board, Incorrect thermostat configuration, Blown low-voltage fuse on control board
How to Fix / Troubleshooting
Safety first: Turn off furnace power before handling thermostat wiring.
- Step 1 – Verify thermostat settings: Ensure the thermostat is set to HEAT and the setpoint is above room temperature. Replace batteries if applicable.
- Step 2 – Check low-voltage fuse: Remove blower door and inspect the 3–5A fuse on the Ducane IFC. Replace if blown, but first inspect thermostat wiring for shorts.
- Step 3 – Test W call at furnace: With power off, remove the W wire from the board. Restore power and briefly jumper R to W at the board. If the furnace starts, the issue is in the thermostat or wiring.
- Step 4 – Inspect thermostat cable: Look for damage along the cable run. Replace if crushed or cut.
Advertisements
Repair Difficulty
Easy
2/5